Updated worldwide glass market study 2024 available now for flat, container glass and tableware

We have updated our international studies on flat glass, container glass and tableware for 2024.

This unique software provides a global overview about glass producers and technical details. Easy to use and clear tables summarize information and data about glass makers such as: Glass types: flat glass, container glass, tableware, production capacities in regions and countries, number of furnaces, furnace types, year of construction, glass types and sub-types, products, project information, special news and downloads.

Further databases supplying demoscopic data and import and export data complete the market survey. Based on these data, prepare individual country profiles with information about local production capacities, local market sizes and expected demand in the future.

Request your offer via plants.glassglobal.com.

Updated container glass study 2024

X

Updated float glass study 2024

X

Further glass studies and reports 2024

X

O diretório de vidro
 

INFO

Essas são as informações básicas da empresa. A empresa fornece informações detalhadas adicionais, tais como Web site, fax e números de telefone, pessoas de contacto, a história e os dados da empresa.

Para obter acesso a essa informação, ou para impressão do perfil de empresa, é preciso ter uma validade "Profile Access" para glassglobal.com. Informações para reservas estão disponíveis no Informaçaos e preços .

login



Informações de contato

Endereço Vasiliou Glass Technologies
28th of October St., Vasiliko
34002 Chalkis
Email Get in contact with Vasiliou Glass Technologies

Produtos / Máquinas
 

  • Standard Glass
  • Noise Reduction
  • Design and Decoration
  • Protection and Safety
  • Structural
  • Energy
  • Marine 
  • Special Glazing

Details: http://www.vasglass.gr/en/content/product-range 


VAS “VASILIOU GLASS TECHNOLOGIES”, a company fully compliant with the current European framework and norms, maintains a thorough and well-documented Factory Production Control system, while operating within two distinct appraisal systems, differentiated by the level of involvement of notified-body organizations in each one of them.

Specifically, VAS “VASILIOU GLASS TECHNOLOGIES” operates under the following systems:
 

System 1:
An independent third-party (notified body) a) determines the product-type and issues the product’s Certificate of Constancy of Performance, which includes all relevant technical documentation and b) performs continuous monitoring, and evaluation of the Factory Production Control system.

 

System 3:
An independent third-party (notified body) specifies product-type on the basis of type-testing. The manufacturer implements and monitors the Factory Production Control System.

CE TEMPERED GLASS ACCORDING TO EN 12150

  • TYPE - Clear Float
  • TYPE - Β1με 1>e>0.25 Coated Low-emissivity
  • TYPE - Β2 με 0.25>e>0.1 Coated Low-emissivity
  • TYPE - Β3 με 0.1>e Coated Low-emissivity
  • TYPE - Patterned

  • CE TEMPERED GLASS ACCORDING TO EN 12150 AND EN 12600 (PENDULUM TEST)

  • TYPE - Clear Float
  • TYPE - Β1με 1>e>0.25 Coated Low-emissivity
  • TYPE - Β2 με 0.25>e>0.1 Coated Low-emissivity
  • TYPE - Β3 με 0.1>e Coated Low-emissivity
  • TYPE - Patterned

  • CE HEAT STRENGTHENED GLASS ACCORDING TO EN 1863

  • TYPE - Clear Float

  • CE TEMPERED GLASS ACCORDING TO EN 12150 AND HEAT SOAK TEST TREATMENT ACCORDING TO EN 14179

  • TYPE - Clear Float
  • TYPE - Β1με 1>e>0.25 Coated Low-emissivity
  • TYPE - Β2 με 0.25>e>0.1 Coated Low-emissivity
  • TYPE - Β3 με 0.1>e Coated Low-emissivity
  • TYPE - Patterned

  • CE LAMINATE SAFETY GLASS ACCORDING TO EN 14449 and EN 12543, PVB

  • EN12600 (Pendulum Test)
  • EN356A (P1A, P2A, P3A, P4A, P5A)
  • EN356B (P6B, P7B, P8B)
  • EN1063 (BR1S/NS, BR2S/NS, BR3S/NS, BR4S/NS, BR5S/NS, BR6S/NS, BR7S/NS)

  • CE LAMINATE SAFETY GLASS ACCORDING TO EN 14449 and EN 12543, SGP

  • EN12600 (Pendulum Test)
  • EN356A (P1A, P2A, P3A, P4A, P5A)
  • EN356B (P6B, P7B, P8B)
  • EN1063 (BR1S/NS, BR2S/NS, BR3S/NS, BR4S/NS, BR5S/NS, BR6S/NS, BR7S/NS)



  •  
  •  

 

erevna
 


CE LAMINATE SAFETY GLASS ACCORDING TO EN 14449 and EN 12543, DG41

  • EN12600 (Pendulum Test)
  • EN356A (P1A, P2A, P3A, P4A, P5A)
  • EN356B (P6B, P7B, P8B)
  • EN1063 (BR1S/NS, BR2S/NS, BR3S/NS, BR4S/NS, BR5S/NS, BR6S/NS, BR7S/NS)

  • CE LAMINATE SAFETY GLASS ACCORDING TO EN 14449 and EN 12543, TPU+PC

  • EN12600 (Pendulum Test)
  • EN356A (P1A, P2A, P3A, P4A, P5A)
  • EN356B (P6B, P7B, P8B)
  • EN1063 (BR1S/NS, BR2S/NS, BR3S/NS, BR4S/NS, BR5S/NS, BR6S/NS, BR7S/NS)

  • CE LAMINATE SAFETY GLASS ACCORDING TO EN 14449 and EN 12543, ACOUSTIC

  • EN12600 (Pendulum Test)
  • EN356A (P1A, P2A, P3A, P4A, P5A)

  • CE LAMINATE SAFETY GLASS ACCORDING TO EN 14449 and EN 12543, SG41

  • EN12600 (Pendulum Test)
  • EN356A (P1A, P2A, P3A, P4A, P5A)

  • CE INSULATING GLASS ACCORDING TO EN 1279

  • Moisture penetration (EN1279-2)
  • Gas concentration and gas leak rate (EN1279-3)